Locate and measure an outside edge.
First, the macro probes a surface to obtain a reference (Z position of the part).
Then, it moves in the specified axis and direction until the edge is detected.
G65 P131 H<axis> E<direction> D<distance>
| H | Axis number to probe:
|
| E | Probe direction:
Must be either +1 or −1. |
| D | Approximate Distance to Edge
|
| J | Overedge
|