Set backlash compensation value if you machine has backlash. Units of backlash compensation values for linear axes are in mm or inch, for rotational axes are in degrees.
Disable: Disables backlash compensation.
External: Controller receives external command for backlash compensation. Currently not supported.
Internal: Enables backlash compensation. Software will generate additional steps necessary for backlash compensation.
If Simulation is enabled in settings under chapter Connection, you can enable or disable the backlash compensation in simulation mode.
Disable: Disables the backlash compensation in simulation mode.
Enable: Enable the backlash compensation in simulation mode.