With this parameter you can set at which speed machine will reference its axes when homing procedure will be executed.
E.g.: We set Speed at 1000mm/min Homing of each axis will be performed at 1000mm/min.
With this parameter you can set at which speed machine will reference its rotary ABC axes when homing procedure will be executed.
Example: We set Speed ABC at 100mm/min Homing of each rotary axis will be performed at 1000mm/min.
After initial reference sensor(limit switch) activation, machine will repeat measurement again, but this time at Low speed.
User can set homing sequence order of axes. Select homing order number for desired axis from drop down menu.
Example: If number 1 is selected for desired axis, then that axis will be homed first.
User can set homing direction of desired axis. Radio button “-” references machine axis in negative direction. Radio button “+” references machine axis in positive direction.
Value inserted is machine position that will be set when reference switch is activated during homing procedure.
User can set home position of axes after homing procedure is completed. These are machine position coordinates.
Example: Move To values are X=0 ; Y=0 and Z=50 After homing procedure of each axis is completed , X and Y axes will be positioned at 0 and Z axis at height 50mm.
This is the distance from the point where limit switch is activated and to the point when it is released.