tng:settings:settings-program_options_events

Program Options - Events

Start From Line

User can define if Spindle, Flood and Mist outputs are restored when using program feature Start From Selected Line.

Restore State

When enabled, complete state will be restored. Software will consider last state to the point of selected program line.

Restore Mist

When enabled, Mist output will be restored. Software will consider last Mist output state (M7/M9) to the point of selected program line.

Restore Flood

When enabled, Flood output will be restored. Software will consider last Flood output state (M8/M9) to the point of selected program line.

Restore Spindle

When enabled, Spindle output will be restored. Software will consider last Spindle output state (M3/M5) to the point of selected program line.

Restore Position

When enabled

Estop

User can define if controller outputs and Spindle, Flood and Mist outputs are turned off when using Estop is activated.

Communication

When enabled, all controller external communication(I2C,Serial,EXT) functionality will be disabled.

Outputs Off

When enabled, all controller outputs will be turned off.

Stop Mist

When enabled, Mist output will be turned off when Estop is activated.

Stop Flood

When enabled, Flood output will be turned off when Estop is activated.

Stop Spindle

When enabled, Spindle output will be turned off when Estop is activated.


OnStart

OnStart script example
This script will print time when program started and other available arguments.
If program is not started from beginning it will move to start position at safe height and display dialog.

#<dt> = DateTime[]
#<hh> = Hour[#<dt>]
#<mm> = Minute[#<dt>]
#<ss> = Second[#<dt>]
(print,OnStart script @ #<hh,0>:#<mm,0>:#<ss,0>)
(print,  Line: #<line,0>)
(print,  PosState: X#<posstate_x,3> Y#<posstate_y,3> Z#<posstate_z,3>)
(print,  Units: #<_units,0>)
(print,  Plane: #<_plane,0>)
(print,  DistanceMode: #<_distancemode,0>)
(print,  DistanceModeIJK: #<_distancemode_ijk,1>)
 
O<chk> if [#<line>]
  (print,  MistState: #<miststate,0>)
  (print,  FloodState: #<floodstate,0>)
  (print,  SpindleState: #<spindlestate,0>)
  (print,  MotorsState: #<motorsstate,0>)
  (print,  LimitsState: #<limitsstate,0>)
 
  #<dstmd> = #<_distancemode>
  G90
 
  G53 G00 Z#<_tooloff_safeheight>
  G53 G00 X#<posstate_x> Y#<posstate_y> 
 
  G09
  (dlgname,Start From Line, opt=1)
  (dlg,Click OK to continue from line #<line,0>, typ=label, x=20, w=250, color=0xffa500)
  (dlgshow)
 
  G53 G00 Z#<posstate_z>
 
  #<_distancemode> = #<dstmd>
 
O<chk> endif

OnEnd

OnEnd script example
This script will print time when program ended and other available arguments.
It will also calculate 'Run Time Correction' factor.

#<dt> = DateTime[]
#<hh> = Hour[#<dt>]
#<mm> = Minute[#<dt>]
#<ss> = Second[#<dt>]
(print,OnEnd script @ #<hh,0>:#<mm,0>:#<ss,0>)
(print,  Line: #<line,0>)
(print,  Runtime: #<runtime,1>)
 
#<cor> = [1 - [#<runtime> - #<_prog_totaltimebest>] / [#<_prog_totaltimeworst> - #<_prog_totaltimebest>]]
(print,  Run Time Correction: #<cor,2>)

OnStop

OnStop script example
This script will turn spindle and coolant off if program is stopped.

(print,OnStop script)
(print,  Line: #<line,0>)
 
M5
M9
tng/settings/settings-program_options_events.txt · Last modified: 2023/10/12 12:31 by planetcnc